Aluminum-shell PTC heating elements
Contact heating for hair tools, wax warmers and appliance assemblies.
Built around the contact surface
An aluminum shell packages the PTC heat source into a contact-heating component. The original LC range includes formats for hair straighteners, curling irons, wax warmers, glue guns and vessel-heating applications. Mechanical contact and heat transfer matter as much as the electrical rating: the same heater can deliver different stabilized power in different assemblies.
| Selection parameter | Published family information |
|---|---|
| Published supply options | 12 / 24 / 110 / 240 V; confirm AC or DC for the selected model |
| Published surface-temperature options | 70–290°C; this is not the final appliance temperature |
| Customization | Envelope, voltage, leads and application-specific temperature |
Published catalog sizes
The original catalog identifies these sizes with numerical “Model No.” references. They are size references, not unique electrical part numbers. Please include the family name, size, voltage and temperature when enquiring.
| Catalog reference | Length (mm) | Width (mm) | Thickness (mm) |
|---|---|---|---|
| 1 | 25 | 20 | 5.3 |
| 2 | 30 | 20 | 5.3 |
| 3 | 40 | 20 | 5.3 |
| 4 | 50 | 20 | 5.3 |
| 5 | 60 | 20 | 5.3 |
| 6 | 80 | 20 | 5.3 |
| 7 | 30 | 25 | 7.5 |
| 8 | 40 | 25 | 7.5 |
| 9 | 50 | 25 | 7.5 |
| 10 | 60 | 25 | 7.5 |
| 11 | 80 | 25 | 7.5 |
| 12 | 40 | 30 | 6.2 |
| 13 | 50 | 30 | 6.2 |
| 14 | 60 | 30 | 6.2 |
| 15 | 80 | 30 | 6.2 |
| 16 | 40 | 35 | 6.2 |
| 17 | 50 | 35 | 6.2 |
| 18 | 60 | 35 | 6.2 |
| 19 | 70 | 35 | 6.2 |
| 20 | 80 | 35 | 6.2 |
| 21 | 50 | 43 | 7.2 |
| 22 | 60 | 43 | 7.2 |
| 23 | 70 | 43 | 7.2 |
| 24 | 80 | 43 | 7.2 |
| 25 | 70 | 63 | 7.2 |
| 26 | 72 | 63 | 7.2 |
| 27 | 80 | 63 | 7.2 |
| 28 | 90 | 63 | 7.2 |
| 29 | 100 | 63 | 7.2 |
What to confirm before ordering
Electrical specification
Nominal voltage, AC/DC, lead length, connector, insulation requirement and target power under agreed test conditions.
Thermal integration
Heating-plate contact, mounting pressure, target appliance temperature, ambient conditions and warm-up expectations.
Sample validation
Verify the heater in the final assembly. PTC self-regulation does not replace appliance controls and safety protection.